Midea air conditioners are popular for their innovation and energy efficiency. However, like all HVAC systems, they can experience occasional issues. When problems occur, the air conditioning unit displays error codes that help users and technicians diagnose and address the malfunction. This comprehensive guide offers a thorough overview of Midea air conditioner error codes, their meanings, and troubleshooting methods to help clear the error.
Table of Content
2 – Understanding Midea Error Codes
3 – Common Midea Aircon Error Codes and Their Meanings
4 – Midea Aircon Advanced Error Codes and Solutions
5 – Troubleshooting Tips for Midea Air Conditioner Error Codes
6 – Overview of the Service Manual for the Midea Aircon Multi Inverter Series
If you are too lazy to read,
CONTACT US NOW
Error codes are an essential part of the modern appliance ecosystem. They simplify the troubleshooting process by providing a quick diagnosis of what might be wrong with the air conditioning unit. By interpreting these codes, users can identify if the issue lies in the indoor or outdoor unit of the air conditioning system, if there is a sensor malfunction, or if electrical problems are present.
Understanding these error codes helps reduce downtime by identifying the problem quickly. It prevents further damage by addressing issues promptly as well as facilitating easier communication with service technicians. It also saves costs by allowing minor problems to be fixed without professional intervention.
Understanding Midea Error Codes
Midea air conditioners are equipped with self-diagnostic systems that display error codes on the indoor unit or remote controller. These alphanumeric codes indicate specific faults, enabling quick and efficient troubleshooting. Midea error codes typically start with a letter (e.g., E, F, P) followed by numbers (e.g., E1, F2, P4).
EXPLORE OUR SERVICES
Click to find out
| Error Code | Cause | Troubleshooting |
|---|---|---|
| E1 – High Pressure Protection | Excessive pressure in the refrigerant system. |
|
| E2 – Indoor Anti-freeze Protection | Evaporator coil temperature is too low. |
|
| E3 – Low Pressure Protection | Low refrigerant pressure or leakage. |
|
| E4 – Indoor Room Temperature Sensor Error | Indoor temperature sensor is in open circuit or has short circuited. |
|
| E5 – Overcurrent Protection | Excessive current in the system. |
|
| E6 – Communication Error | Loss of communication between indoor and outdoor units. |
|
| E8 – Power Phase Protector Fault | Midea cassette aircon has an airflow or electrical issue. |
|
| Error Code | Cause | Troubleshooting |
|---|---|---|
| F0 – Refrigerant Leakage | Insufficient refrigerant due to leakage. |
|
| F1 – Indoor Ambient Sensor Fault | Malfunctioning ambient temperature sensor. |
|
| F2 – Outdoor Temperature Sensor Fault (Condenser) | Condenser coil temperature sensor is in open circuit or has short circuited. |
|
| F3 – Outdoor Temperature Sensor Fault (Compressor) | Compressor discharge temperature sensor is in open circuit or has short circuited. |
|
| F4 – Outdoor unit EEPROM parameter error | N/A | Contact a technician to reprogram or replace the EEPROM. |
| F5 – Outdoor Fan Motor Speed Fault | The outdoor fan motor speed is operating outside the normal range. |
|
| F6 – Indoor Temperature Sensor Fault | Evaporator coil outlet temperature sensor is in open circuit or has short circuited. |
|
| P0 – IPM Malfunction | Wiring defect or fault in the outdoor fan motor or compressor. |
|
| P1 – Voltage Protection | Voltage fluctuations or abnormal supply. |
|
| P2 – Water Drainage Issue | Clog in the drain line. |
|
| P4 – Inverter Module Protection | Overheating or malfunction of inverter module. |
|
| H6 – Indoor Fan Motor Malfunction | Faulty or locked indoor fan motor. |
|
While some error codes may require professional intervention, there are basic troubleshooting steps you can take:
- Reset the air conditioning unit. Sometimes, simply turning off the air conditioner and restarting it can clear minor errors.
- Check for power supply issues. Ensure there are no power fluctuations or tripped circuit breakers.
- Inspect for blockages. Look for obstructions in the air filters, fans, or condensate drain lines.
- Clean the air conditioner. Try to regularly clean the air filters, condenser coils, and drainage pipes to prevent errors related to airflow or clogging.
- Inspect the wiring and sensors. Loose wiring jacks, damaged wires, and disconnected or defective sensors are common causes of error codes. Secure and replace components as needed.
For more information, refer to your Midea air conditioner’s service manual or go here. Alternatively, feel free to use the following information:

Below is a summary and overview of the contents of the SM_MULTI_R410A_3D INV_SG_NA_181207 service manual of the Midea Multi Inverter Series, the entirety of which you can download here.
- Safety Precautions
General Warnings:
Prevent personal injury, property, or unit damage by following all safety instructions.
Ensure only qualified personnel handle installation, maintenance, or repairs.
Emergency Situations:
Shut off power if there are gas leaks, smoke, or abnormal noises.
Avoid inserting hands or objects into air inlets/outlets during operation.
Installation Warnings:
Use dedicated electrical circuits and ensure proper grounding.
Check for potential hazards around the installation site (falling risks, unstable areas).
Operation and Maintenance:
Do not modify the unit’s electrical components or wiring.
Avoid using damaged power cords or exposed wiring.
- Specifications
Model References and Capacities:
Lists indoor and outdoor unit models with capacities (9K, 12K, 21K, 28K Btu/h).
Pipe Length and Drop Height:
Maximum pipe length (60-80m) and height difference between indoor and outdoor units (15m).
Guidelines for additional refrigerant charges for longer pipe lengths.
Refrigerant Piping:
Details on pipe diameters (liquid and gas) based on model type.
Electrical Wiring Diagrams:
Indoor and outdoor wiring layouts.
Lists key electrical components (compressors, fans, expansion valves).
- Product Features
Operation Modes:
Cooling, Heating, Fan, Auto, Drying: Describes how the air conditioner behaves in each mode.
Forced Operation: Enables automatic mode for troubleshooting or emergencies.
Safety Features:
Compressor protection with three-minute delays.
Overheat and overcurrent protection to avoid compressor damage.
Automatic shutoff if indoor fan speed drops below 300 RPM.
Advanced Functions:
Auto-Restart: Restores previous settings after power outages.
Sleep Mode: Gradually adjusts temperature for enhanced comfort during sleep.
Follow Me: Remote control temperature sensing feature for more precise cooling.
Ionizer: Helps clean and purify air (optional).
Display Indicators:
LED indicators for different functions, including error codes, defrost, and timer settings.
- Maintenance
First-Time Installation Checks:
Leak testing methods using soap water or vacuum pumps.
Air purging using vacuum pumps to ensure proper refrigerant flow.
Refrigerant Recharging:
Steps for recharging refrigerant based on pressure readings and weights.
Requires proper tools (vacuum pump, manifold gauge).
Re-Installation Procedures:
Guides for disassembling and reinstalling indoor and outdoor units.
Collecting refrigerant back into the outdoor unit before removal.
- Troubleshooting
General Troubleshooting Steps:
Comprehensive troubleshooting guide for common errors (unit not starting, fan malfunctions, poor cooling).
Solutions for issues like refrigerant leaks, sensor errors, and compressor faults.
Error Codes and Diagnosis:
Indoor Unit Error Codes (E0 to P6): Covers EEPROM errors, fan speed abnormalities, and sensor malfunctions.
Outdoor Unit Error Codes (E0 to P6): Diagnoses compressor current overload, inverter errors, and communication issues.
Field Maintenance:
Flowcharts for diagnosing errors based on symptoms.
Compressor, fan, and sensor testing procedures.
- Error Diagnosis Without Codes
Remote Maintenance:
Checklist of potential causes for common problems (power failures, loose connections, sensor faults).
Field Maintenance:
Identifies compressor or fan-related issues through direct inspection.
Testing methods for refrigerant levels and circuit malfunctions.
OUR TESTIMONIALS



While some issues can be resolved with basic troubleshooting, others require the expertise of a certified technician. Call for professional help if:
- The error code persists after resetting the unit.
- There are signs of refrigerant leaks or unusual noises.
- Electrical faults or compressor errors are detected.
- You are unsure about the necessary repairs.
Aircon Error Codes for other brands

At Silverback Aircon, our friendly staff and technicians will provide you with the most efficient service for the best and affordable price. Furthermore, all of our spare parts are tested, refurbished and commissioned before selling it to the customers (you). Therefore, you can trust us with all your aircon servicing needs. For any enquiries with regards to Midea Aircon Error Code, or other brands, don’t be hesitant to contact us. Our friendly staff will be able to provide you with all the necessary information. Meanwhile, you can book an appointment with us for a site visit so that we will be able to give our professional advice to you. We also provide other aircon services as well.
To minimize the occurrence of error codes and ensure the longevity of your LG air conditioner, follow these maintenance tips:
- Do regular AC maintenance. Schedule routine inspections and servicing.
- Clean or replace air filters every 1 to 3 months. To clean, unplug the AC unit, open the aircon’s front hatch, unclip the AC filter, scrub thoroughly under soapy water, rinse and dry completely before putting it back.
- Ensure the air conditioner is installed correctly by certified professionals.
- Monitor the AC refrigerant levels. Regularly check and maintain appropriate refrigerant levels.
- Keep the area surrounding your air conditioner clean and unobstructed. Make sure that both indoor and outdoor units are free from debris and obstructions.
Midea air conditioner error codes are a valuable tool for diagnosing and resolving issues efficiently. By understanding these codes and taking appropriate action, users can maintain the performance and longevity of their air conditioning units. Whether it’s a simple sensor error or a more complex system malfunction, this guide provides the essential information needed to address Midea aircon issues with confidence.