Mitsubishi Heavy Industries Error Codes Introduction

Ever waking up in the morning only to see a set of weird error codes on your Mitsubishi Heavy Industries Aircon? Unsure what is it and how do you troubleshoot it? Rest assured, you can always get into contact with an aircon technician from Silverback Aircon to request for a site visit, aircon servicing or even aircon repair.  This article acts as a guide to bring you through some of the possible Mitsubishi Heavy Industries Aircon Error Codes. Additionally, it also gives you the possible actions that could be taken to resolve these issues.

However, if you are the type of hands-on personnel and wishes to take action immediately, you can contact us here. Alternatively, feel free to click on the button below to contact us via WhatsApp. We will be able to use our expertise to provide our professional advice to you. Additionally, feel free to give us a call at +65 9651 5152 for a free consultation.

MHI

Facing Mitsubishi Heavy Industries Error Code?

 

CONTACT US NOW

Mitsubishi Heavy Industries vs Mitsubishi Electric

Before we dive straight to the topic, you must be wondering about the differences between Mitsubishi Heavy Industries Aircon & Mitsubishi Electric Aircon. Here is an overview of the differences between both of them.

Mitsubishi Electric is known to have develop a high-quality and reliable AC System. This brand delivers some of the most advanced air-conditioner units around Singapore. Additionally, they are also known to be durable enough. On the other hand, Mitsubishi Heavy Industries develop reliable systems that can last longer as compared to Mitsubishi Electric. In addition, their units are able to serve bigger rooms with no concerns with regards to the size of the room. Some of the benefits includes Better Performance, Longer Experience, Cost Effective, etc.

Mitsubishi Heavy Industries

Mitsubishi Electric

OUR TESTIMONIALS

Facebook Review
Carousell Review
Qoo10 Review

Possible Mitsubishi Heavy Industries Aircon Error Codes

 

When the AC unit performs an emergency stop, the reason is indicated by a set of error code. The possible Mitsubishi Heavy Industries Aircon Error Codes is split into 2 portion. However, it is highly dependent on the brand and model of your aircon. As a result, there’ll definitely be some differences.

Model: SCM40, 45, 50, 60, 71, 80

Type of Error Codes Description Possible Causes
E1 Error of Wired Remote Controller Wiring

– Broken Wire Remote Controller Wire

– Defective Indoor PCB

E5 Error of Signal Transmission

– Defective Power Supply

– Broken Signal Wire

– Defective Indoor/Outdoor Sub PCB

E9 Drain Trouble

– Defective Drain Pump

– Broken Drain Wire

– Defective Indoor PCB Faulty

E16 Indoor Fan Motor Error

– Defective Fan Motor

– Poor Connector Connection

E35 Cooling High Pressure Protection

– Overload Operation

– Overcharge

– Broken Outdoor Heat Exchange Sensor Wire

– Service Valve is closed

E36 Overheating on Compressor

– Gas Shortage

– Defective Discharge Pipe Sensor

– Service Valve is closed

E37 Outdoor Heat Exchange Sensor Error

– Broken Heat Exchange Sensor Wire

– Poor Connector Connection

– Outdoor Main PCB Faulty

E38 Outdoor Air Temperature Sensor Error

– Broken Outdoor Air Temperature Sensor Wire

– Poor Connector Connection

– Outdoor Main PCB Faulty

E39 Discharge Pipe Sensor Error

– Broken Discharge Pipe Sensor Wire

– Poor Connector Connection

– Outdoor Main PCB Faulty

E42 Current Cut

– Compressor Locking

– Open phase on compressor output

– Short circuit on power transistor service valve is closed

E45 Outdoor Sub PCB Communication Error

– Outdoor Sub PCB Faulty

– Poor connector connection between outdoor Main PCB and Sub PCB

E47 Active Filter Voltage Error – Defective Active Filter
E48 Outdoor Fan Motor Error

– Defective Fan Motor

– Poor Connector Connection

E51 Power Transistor Error – Broken Power Transistor
E53 Outdoor Suction Pipe Sensor Error

– Broken Suction Pipe Sensor Wire

– Poor Connector Connection

– Outdoor Sub PCB Faulty

E57 Refrigeration Cycle System Protective Control

– Service Valve is closed

– Insufficient Refrigerant

E58 Current Safe Stop

– Overload Operation

– Overcharge

– Compressor Locking

E59 Trouble of Outdoor Unit

– Broken Compressor Wire

– Compressor Blockage

E60 Rotor Lock

– Defective Compressor

– Open Phase on Compressor

– Defective Outdoor PCB

Model: SCM100,125

Most of the error codes is similar to the ones above. The table below shows the Mitsubishi Heavy Industries Aircon Error Codes that are different:

 

Type of Error Codes Description Possible Causes
E35 Cooling High Pressure Protection

– Overload Operation

– Overcharge

– Broken High Pressure Sensor Wire

– Service Valve is closed

E40 Heating High Pressure Protection

 – Overload Operation

– Overcharge

– Broken High Pressure Sensor Wire

– Service Valve is closed

E41  Power Transistor Error  – Power Transistor Overheat
E51 Inverter and Fan Motor Anamoly

– Outdoor Inverter/Control PCB Faulty

– Outdoor Fan Motor Faulty

E54  High Pressure Sensor Error  – Broken High Pressure Sensor Wire

FACING THESE AIRCON PROBLEMS?

aircon making noise
Noisy Aircon?
Aircon Thermistor Issues
Aircon Thermistor Issues?
Aircon Bad Odour
Aircon Bad Odour?
aircon compressor repair
Aircon Compressor Repair?

Mitsubishi Heavy Industries Aircon Light-Blinking?

 

Alternatively, you can see whether the light is blinking, and it will help you in determining what is the type of error. Meanwhile, the table below shows some of the possible errors observed via number of light blinking:

RUN Light TIMER Light Description
Light Up Flash 1 time Power Cut
Flashes 2 times Outdoor Unit Error
Flashes 3 times Over Current (Safe Current)
Flashes 4 times Power Transistor Failure
Flashes 5 times Compressor Overheat
Flashes 6 times Error of communication between Indoor & Outdoor Units
Flash 1 time Light Up Indoor Heat Exchange Sensor Error
Flashes 2 times Room Temperature Sensor Error
Flashes 5 times Voltage Error
Flashes 6 times Indoor Fan Motor Error
Continuous Flashing Flash 1 time Outdoor Air Temperature Sensor Error
Flashes 2 times Outdoor Heat Exchange Pipe Sensor Error
Flashes 4 times Vent Pipe Sensor Error
Flashes 2 times Flashes 2 times Rotor Lock

However, in the situation that none of the above matches your scenario, feel free to contact us directly for advice and consultation. We will be glad to offer you our help.

Conclusion :

In conclusion, an error code will usually be displayed on the Room AC if any abnormal actions is observe. As a result, being able to identify the type of Mitsubishi Heavy Industries Aircon Error Codes helps you to accurately link up with the technician. In addition, the technician will be able to prepare and bring the necessary spare parts needed during the appointment. Meanwhile, feel free to contact us at +65 9651 5152 if you have any other queries or even to schedule for a Aircon Repair Service.

EXPLORE OUR SERVICES

Click to find out

Aircon Error Codes for other brands

FAQ

Why is my mitsubishi heavy industries aircon light blinking?

The possible errors can be determined via the number of times the light blinks.

light up + flash 1 time : power cut.  flash 2 times : outdoor unit error. flash 3 times : over current. flash 4 times : power transistor failure. flashes 5 times : compressor overheat. flashes 6 times : error of communication between indoor and outdoor units.

for other combinations, you may refer to the table above.


Why is my mitsubishi heavy industries aircon not cold?

When such a situation occurs, it may be due to a clogged air filter, a dirty condensor coil, a defective compressor or even a busted thermostat. There can also be other reasons and it is best to contact us for help, given that we have a team of experienced and professional technicians who are ready to help.


How to maintain my mitsubishi heavy industries aircon?

It is recommended that you regularly clean the air filters of your  mitsubishi heavy industries aircon. You should change the air filter once a month, and check if the air conditioning coils are clean. You  also need to flush drain channels, as a clogged drainage system may affect the aircon’s ability to reduce humidity.

A good idea would be to hire professionals to offer you maintenance and washing services. Here at silverback aircon, we are dedicated to ensuring the health and maintenance of your air conditioners.